OSCR

Comparison of subject-to-template registration schemes using CT and MR radiotherapy images with brain lesions.

Code ↔ Paper

The paper beside its authors' code: matches between them have not been computed for this paper yet.

Paper

Loaded from Europe PMC by your browser; OSCR does not store it: doi.org · Europe PMC

The paper is loaded when this pane is shown.

The authors' code

Shell · 49 lines · 2.6 KB · no license

  1. #!/bin/bash
  2. SELF_DIR=$(dirname "$(readlink -f "$0")")
  3. SUBJECTS_DIR=${SELF_DIR}/Nifti
  4. SEGMENTATIONS_DIR=${SELF_DIR}/Segmentations
  5. TEMPLATE_DIR=${SELF_DIR}/Template/
  6. MNI_DATA_DIR=${SELF_DIR}/MNI_data/
  7. REG_PAR_FILE_AFF=${SELF_DIR}/mirtk/mirtk-aff-dual.cfg
  8. SCHEME=Dual-Template-linear
  9. for sub_dir in ${SUBJECTS_DIR}/CoDe-B-Rad*; do
  10. sub_id=`basename ${sub_dir}`
  11. for timepoint in 'BL' '3M' '6M' '9M' '12M'; do
  12. if [[ -f "${sub_dir}/${timepoint}/CT.nii.gz" ]] && [[ -f "${sub_dir}/${timepoint}/MR.nii.gz" ]]; then
  13. out_dir=${MNI_DATA_DIR}/${sub_id}/${timepoint}
  14. if [[ ! -d ${out_dir} ]]; then
  15. mkdir -p ${out_dir}
  16. fi
  17. if [[ ! -f ${out_dir}/${SCHEME}.processed ]]; then
  18. echo -n "[Subject ${sub_id}] Affinely registering ${timepoint} CT and MR image to CT and MR templates simultaneously ... "
  19. mirtk register ${TEMPLATE_DIR}/template_sCT.nii.gz ${TEMPLATE_DIR}/template_T1w.nii.gz ${sub_dir}/${timepoint}/CT_in_MR_space.nii.gz ${sub_dir}/${timepoint}/MR.nii.gz -parin ${REG_PAR_FILE_AFF} -dofout ${out_dir}/${SCHEME}_CT_MR_to_Dual_template_aff.dof.gz -v 0
  20. echo "done"
  21. echo -n "[Subject ${sub_id}] Transforming ${timepoint} MR image to MR template ... "
  22. mirtk transform-image ${sub_dir}/${timepoint}/MR.nii.gz ${out_dir}/${SCHEME}_MR.nii.gz -target ${TEMPLATE_DIR}/template_T1w.nii.gz -dofin ${out_dir}/${SCHEME}_CT_MR_to_Dual_template_aff.dof.gz
  23. echo "done"
  24. echo -n "[Subject ${sub_id}] Transforming ${timepoint} CT image to MR template ... "
  25. mirtk transform-image ${sub_dir}/${timepoint}/CT_in_MR_space.nii.gz ${out_dir}/${SCHEME}_CT.nii.gz -target ${TEMPLATE_DIR}/template_T1w.nii.gz -dofin ${out_dir}/${SCHEME}_CT_MR_to_Dual_template_aff.dof.gz
  26. echo "done"
  27. echo -n "[Subject ${sub_id}] Transforming ${timepoint} RTDOSE_full image to MR template ... "
  28. mirtk transform-image ${sub_dir}/${timepoint}/RTDOSE_full_in_MR_space.nii.gz ${out_dir}/${SCHEME}_RTDOSE_full.nii.gz -target ${TEMPLATE_DIR}/template_T1w.nii.gz -dofin ${out_dir}/${SCHEME}_CT_MR_to_Dual_template_aff.dof.gz
  29. echo "done"
  30. echo -n "[Subject ${sub_id}] Transforming ${timepoint} MALPEM segmentation to MR template space ... "
  31. mirtk transform-image ${SEGMENTATIONS_DIR}/${sub_id}/${timepoint}/MR_MALPEM_lesion_masked.nii.gz ${out_dir}/${SCHEME}_MR_MALPEM_lesion_masked.nii.gz -target ${TEMPLATE_DIR}/template_T1w.nii.gz -dofin ${out_dir}/${SCHEME}_CT_MR_to_Dual_template_aff.dof.gz -interp NN
  32. echo "done"
  33. touch ${out_dir}/${SCHEME}.processed
  34. else
  35. echo "Scheme '${SCHEME}' data for timepoint '${timepoint}' of subject '${sub_id}' already exists. Skipping."
  36. fi
  37. fi
  38. done
  39. done

compute_MNI_data_Dual_Template_linear.sh, no license · at the source

Overview

Authors: Anna Bangiri1,2, Stefanie Thust1,2,3,4, Paul S Morgan1,2,3, Stefan Pszczolkowski1,3
ORCID iDs: Stefanie Thust
  1. School of Medicine, University of Nottingham, Nottingham, United Kingdom
  2. Nottingham University Hospitals NHS Trust, Nottingham, United Kingdom
  3. Nottingham NIHR Biomedical Research Centre, University of Nottingham, Nottingham, United Kingdom
  4. Department of Translational Neuroscience and Stroke, UCL Queen Square Institute of Neurology, London, United Kingdom
Journal: Frontiers in neuroscience, volume 20, article 1858490
Dates: received 17 April 2026; accepted 6 July 2026; published online 28 July 2026
Type: Research article · Language: English
License: CC BY
Identifiers: DOI 10.3389/fnins.2026.1858490 · PMID 42582330 · PMCID PMC13457462 · OpenAlex W7171566683
Open access: gold, a free copy (OpenAlex)
Status: code verified (how the code is found and verified)
Categories: other (modality), human (organism)
Methods: Statistics, Machine learning
Keywords: CT, MRI, radiosurgery, radiotherapy, registration, voxel-based analysis
Topic: Advanced Radiotherapy Techniques (Radiation, Physics and Astronomy), according to OpenAlex
Funding: Wellcome Trust (223508/Z/21/Z)
Citations: not cited yet (Europe PMC); 44 references in the paper

Abstract

Introduction: Voxel-based analyses have been used more widely in radiotherapy in recent years. The purpose of this study is to compare eight different methods of registering images on to a template space for such analyses. A novel way, using both CT and MR data, is proposed.

Methods: CT and MR brain images from 85 participants in the CoDe-B-Rad study (NCT06466720) were registered on an age-specific template. The registration schemes used included sCT-Template (linear and non-linear); MR-Template (linear, non-linear, masked, and enantiomorphic); and Dual-Template (linear and non-linear). The registrations were compared qualitatively and quantitatively against the template MR images with scores ranging from 1 (lowest) to 5 (highest) and quantitatively (via Jaccard, ASD, and HD95).

Results: Qualitatively, the best registration scheme was the Dual-Template-non-linear registration, with 60 participants scoring above 4. The second best was the MR-Template-enantiomorphic, with 53 participants scoring above 4. Quantitatively, the Dual-Template-non-linear method outperformed on the mean (±SD) for the ASD and HD95, with 0.918 (±0.1774) and 2.965 (±0.5392) respectively. For ASD the difference compared to other methods was significant (p = 0.03). The MR-Template-masked outperformed on the Jaccard mean (±SD), median (IQR), and ASD, achieving values of 0.567 (±0.0557), 0.555 (0.055), and 0.808 (0.162) respectively. The Dual-Template-non-linear and MR-Template-masked and non-linear had the same result for the median HD95: 2.639. The performance of all linear schemes was inadequate both quantitatively and qualitatively. All non-linear registration schemes had issues with distortions of tissue and landmarks, however, for the Dual-Template scheme these were minimal.

Conclusion: The Dual-Template-non-linear registration scheme is a new way of registering lesioned brain images for use with voxel-wise techniques in radiotherapy, which utilises both CT and MR image data. The scheme provides fidelity of the underlying soft tissue as well as the surrounding skull, minimising anatomical and dosimetric distortions.

Reproduced under the paper's license (CC BY), from the paper cited above.

Repository

Its files are read in the Code ↔ Paper reader above.

OSF 5upq8

License: none: the authors keep all their rights
State: the link answers, verified on 27 September 2026
Evidence: files inventoried
Languages: Shell (10)
Size: 19 files, 10 scripts
Software Heritage: not checked
Found in: “Data availability statement”
Not found: README, license file, CITATION.cff, environment file, tests, continuous integration, documentation
Availability: 1 check, the latest on 27 September 2026: the link answers (HTTP 200)
  • 27 September 2026: the link answers (HTTP 200)
10 files

The paper's code and data availability statement is in the Data section.

Tracing map

Proposed by the machine: these links were found in the paper and verified at the source, without human review. The map will receive a Zenodo DOI once one of the paper's authors has validated it with their ORCID.

What the map holds:

  • 1 repository of the authors' code, each at its verified commit, with its license and how the link was found in the paper;
  • 10 scripts, each with its path and the digest of its content;
  • no match between paragraphs and code yet;
  • neither the text of the paper nor the code itself.

Its JSON (tracing-map.json) is deposited on Zenodo with its DOI once the map is validated.

Data

No dataset and no data link were found in the paper.

Data availability statement

The defaced image sets, along with the raw numerical data for the analysis and the scripts have been shared in a publicly available depository, available at: https://doi.org/10.17605/OSF.IO/5UPQ8.

Reproduced under the paper's license (CC BY), from the paper cited above.

Versions

The history of this record: each version stored by the harvester or made by a correction of its authors or of the maintainers of its code, and what changed in its facts. The texts of the paper (its abstract, its availability statements) are not part of it; versions that changed only those are not listed.

Version 1, 27 September 2026: the first record

Recorded: type, language, journal, volume, pages, dates, 4 authors, 6 keywords, 1 funder, 37 references.

Cite

This paper

Bangiri, A., Thust, S., Morgan, P. S., & Pszczolkowski, S. (2026). Comparison of subject-to-template registration schemes using CT and MR radiotherapy images with brain lesions. Frontiers in neuroscience, 20, 1858490. https://doi.org/10.3389/fnins.2026.1858490

BibTeX

@article{bangiri2026comparison,
author = {Bangiri, Anna and Thust, Stefanie and Morgan, Paul S and Pszczolkowski, Stefan},
title = {{Comparison of subject-to-template registration schemes using CT and MR radiotherapy images with brain lesions}},
journal = {Frontiers in neuroscience},
year = {2026},
month = jul,
volume = {20},
pages = {1858490},
publisher = {Frontiers Media SA},
issn = {1662-4548},
doi = {10.3389/fnins.2026.1858490},
url = {https://doi.org/10.3389/fnins.2026.1858490},
pmid = {42582330},
pmcid = {PMC13457462}
}

RIS

TY - JOUR
AU - Bangiri, Anna
AU - Thust, Stefanie
AU - Morgan, Paul S
AU - Pszczolkowski, Stefan
TI - Comparison of subject-to-template registration schemes using CT and MR radiotherapy images with brain lesions
T2 - Frontiers in neuroscience
J2 - Front Neurosci
PY - 2026
DA - 2026/07/28
VL - 20
SP - 1858490
SN - 1662-4548
PB - Frontiers Media SA
DO - 10.3389/fnins.2026.1858490
UR - https://doi.org/10.3389/fnins.2026.1858490
LA - en
ER -

CSL-JSON

{
"id": "10.3389/fnins.2026.1858490",
"type": "article-journal",
"title": "Comparison of subject-to-template registration schemes using CT and MR radiotherapy images with brain lesions",
"container-title": "Frontiers in neuroscience",
"author": [
{
"family": "Bangiri",
"given": "Anna"
},
{
"family": "Thust",
"given": "Stefanie"
},
{
"family": "Morgan",
"given": "Paul S"
},
{
"family": "Pszczolkowski",
"given": "Stefan"
}
],
"container-title-short": "Front Neurosci",
"volume": "20",
"page": "1858490",
"DOI": "10.3389/fnins.2026.1858490",
"PMID": "42582330",
"PMCID": "PMC13457462",
"ISSN": "1662-4548",
"publisher": "Frontiers Media SA",
"URL": "https://doi.org/10.3389/fnins.2026.1858490",
"language": "en",
"issued": {
"date-parts": [
[
2026,
7,
28
]
]
}
}

The tracing map gets a citation of its own once an author has validated it and it has a DOI.

Similar papers

The papers with a page that share the most with this one: the tools found in their code, their categories, datasets, cited references and authors, the rarest counting most.

[1] doi:10.1007/s00234-021-02875-9 [code]
Stroke population-specific neuroanatomical CT-MRI brain atlas.
Journal: Neuroradiology
In common: other, 6 references
[2] doi:10.1038/s41467-025-65317-7 [code]
Solving the where problem and quantifying geometric variation in neuroanatomy using generative diffeomorphic mapping.
Journal: Nature communications
In common: 5 references
[3] doi:10.1093/neuonc/noae017 [code]
Glioblastoma and radiotherapy: A multicenter AI study for Survival Predictions from MRI (GRASP study).
Journal: Neuro-oncology
In common: author Stefanie Thust
[4] doi:10.1016/j.neuropsychologia.2025.109067 [code]
From MRIcro to MRIcron: The evolution of neuroimaging visualization tools.
Journal: Neuropsychologia
In common: 4 references
[5] doi:10.1016/j.nicl.2022.103305
The impact of etiology in lesion-symptom mapping - A direct comparison between tumor and stroke.
Journal: NeuroImage. Clinical
In common: 4 references
[6] doi:10.1162/imag.a.6 [code]
Evaluating lesion-specific preprocessing pipelines for rs-fMRI in stroke patients: Impact on functional connectivity and behavioral prediction.
Journal: Imaging neuroscience (Cambridge, Mass.)
In common: 4 references
[7] doi:10.1093/brain/awac126 [code]
Post-acute blood biomarkers and disease progression in traumatic brain injury.
Journal: Brain : a journal of neurology
In common: other, 3 references
[8] doi:10.1038/s42003-022-03880-1
Choice of Voxel-based Morphometry processing pipeline drives variability in the location of neuroanatomical brain markers.
Journal: Communications biology
In common: 4 references
[9] doi:10.1038/s43588-026-00953-7 [code]
deepmriprep: voxel-based morphometry preprocessing via deep neural networks.
Journal: Nature computational science
In common: 4 references
[10] doi:10.1093/braincomms/fcac252 [code]
Brain age predicts long-term recovery in post-stroke aphasia.
Journal: Brain communications
In common: 3 references

Contribute

The authors of this paper can claim it, correct its record and validate its tracing map, and the maintainers of its code (its owner, or a public member of its organization) correct what it says of their repository; anyone signed in can ask for its removal. Every request goes to OSCR's own machine, which answers it; your account page follows them.

Sign in with ORCID to claim this paper as one of its authors, correct its record or validate its tracing map: when the paper's metadata lists your ORCID iD, you are recognized at once. Maintainers of its code: sign in with GitHub, then claim the repository on your account page.

Add the badge to the code's README

OSCR: the badge of this paper

If you are an author or a maintainer of this paper's code, you can add this badge. It says what OSCR knows of the paper (its code, its validated tracing map) and links the code to this page. Paste one of these snippets under the README's title. Keep the two marks around it, so that the badge can be replaced in place and is never added twice. OSCR changes nothing in your repository.

Markdown
<!-- oscr-badge:start -->
[![OSCR](https://openscicode.org/badge/doi/10.3389/fnins.2026.1858490.svg)](https://openscicode.org/badge/doi/10.3389/fnins.2026.1858490)
<!-- oscr-badge:end -->
reStructuredText
.. oscr-badge:start

.. image:: https://openscicode.org/badge/doi/10.3389/fnins.2026.1858490.svg
   :target: https://openscicode.org/badge/doi/10.3389/fnins.2026.1858490
   :alt: OSCR

.. oscr-badge:end
HTML
<!-- oscr-badge:start -->
<a href="https://openscicode.org/badge/doi/10.3389/fnins.2026.1858490"><img src="https://openscicode.org/badge/doi/10.3389/fnins.2026.1858490.svg" alt="OSCR"></a>
<!-- oscr-badge:end -->

If you choose to, you can have the badge kept up to date for you, with oscr badge --write from the command line or with the GitHub Action in your repository's workflows. Every other form and option (a card, AsciiDoc, LaTeX, shields.io) is on the badge page.

Request its removal

To ask OSCR to remove this record, the copies of its authors' scripts or its tracing map, use the removal request page: signed in, you say who you are, what to remove and why, then review and confirm the request. Published rules decide every request (how).

Discussion, reproductions, activity

Discussion: code errors and mismatches between the code and the paper about this paper and its code, from readers and its authors, beside the paper and its tracing map.

Report a mismatch between the code and the paper · Report a code error (signed in)

Reproductions: reports from readers who ran the authors' code and did not get the paper's result, what they ran, with which environment, commit and data.

Report a reproduction failure (signed in)

Activity: what happens around this paper: new versions of its record, its map's validation, discussions and reproductions. It opens with sign-in.