OSCR

A novel distortion-matched anatomical imaging sequence for high-fidelity functional mapping in submillimeter-resolution fMRI.

Code ↔ Paper

The paper beside its authors' code: matches between them have not been computed for this paper yet.

Paper

Loaded from Europe PMC by your browser; OSCR does not store it: doi.org · Europe PMC

The paper is loaded when this pane is shown.

The authors' code

MATLAB · 100 lines · 3.9 KB · no license

  1. % ========================================================================
  2. % * Function: h1 = cmp_subpx_prof( mp2rage_i, mp2epiu_i, mp2epic_i, n_lines, n_sample )
  3. % - draw sub-pixel line profiles
  4. %
  5. % * Input :
  6. % --------------------------------------------------------------
  7. % | Description
  8. % --------------------------------------------------------------
  9. % mp2rage_i | MP2RAGE image (2D) (*.nii)
  10. % mp2epiu_i | MP2EPI-uncorrected image (2D) (*.nii)
  11. % mp2epic_i | MP2EPI-corrected image (2D) (*.nii)
  12. % n_lines | number of lines
  13. % n_sample | number of samples per line
  14. % --------------------------------------------------------------
  15. %
  16. % * Output :
  17. % --------------------------------------------------------------
  18. % | Description
  19. % --------------------------------------------------------------
  20. % hi | figure handle
  21. % --------------------------------------------------------------
  22. %
  23. % * Dev.: Seong Dae Yun ([email hidden])
  24. % * Ref.: Yun et al. A Novel Distortion-Matched Anatomical Imaging Sequence for
  25. % High-Fidelity Functional Mapping in Submillimeter-Resolution fMRI.
  26. % Sci Rep. 2026. doi: 10.1038/s41598-026-58377-2. in press.
  27. % ========================================================================
  28. function hi = cmp_subpx_prof( mp2rage_i, mp2epiu_i, mp2epic_i, n_lines, n_sample )
  29. % Get coordinates
  30. hi = figure ;
  31. imshow( mp2rage_i, [0 max( mp2rage_i(:) )*0.75] )
  32. [x_input, y_input] = ginput(2);
  33. % Get profiles
  34. del_xy = 0.05 ;
  35. prof_mp2rage = zeros( n_sample, n_lines ) ;
  36. prof_mp2epiu = zeros( n_sample, n_lines ) ;
  37. prof_mp2epic = zeros( n_sample, n_lines ) ;
  38. for ii = 1 : 1 : n_lines
  39. x_coords = x_input - floor( n_lines/2 )*del_xy + (ii-1)*del_xy ;
  40. y_coords = y_input - floor( n_lines/2 )*del_xy + (ii-1)*del_xy ;
  41. h1 = drawpolyline( gca, 'Position', [x_coords y_coords], 'Color', [1.0 1.0 0.0], 'LineWidth', 4 ) ;
  42. h1.MarkerSize = 0.01 ;
  43. h1.InteractionsAllowed = 'none' ;
  44. prof_mp2rage( :, ii ) = improfile( mp2rage_i, x_coords, y_coords, n_sample, 'bicubic' ) ;
  45. prof_mp2epiu( :, ii ) = improfile( mp2epiu_i, x_coords, y_coords, n_sample, 'bicubic' ) ;
  46. prof_mp2epic( :, ii ) = improfile( mp2epic_i, x_coords, y_coords, n_sample, 'bicubic' ) ;
  47. end
  48. % Mean +- std
  49. prof_a_mp2rage = mean( prof_mp2rage, 2 ) ;
  50. prof_s_mp2rage = std ( prof_mp2rage, 0, 2 ) ;
  51. prof_a_mp2epiu = mean( prof_mp2epiu, 2 ) ;
  52. prof_s_mp2epiu = std ( prof_mp2epiu, 0, 2 ) ;
  53. prof_a_mp2epic = mean( prof_mp2epic, 2 ) ;
  54. prof_s_mp2epic = std ( prof_mp2epic, 0, 2 ) ;
  55. % Display
  56. idx_GM_start_mp2rage = 30 ;
  57. idx_GM_start_mp2epiu = 52 ;
  58. idx_GM_start_mp2epic = 30 ;
  59. figure( 'Color', 'w' ) ;
  60. hold on ;
  61. grid on ;
  62. x_axis = linspace( 0, size( prof_mp2epic, 1 )-1, size( prof_mp2epic, 1 ) )' ;
  63. x_patch = [x_axis; flipud(x_axis)] ;
  64. y_patch_mp2rage = [prof_a_mp2rage + prof_s_mp2rage; flipud(prof_a_mp2rage - prof_s_mp2rage)];
  65. y_patch_mp2epiu = [prof_a_mp2epiu + prof_s_mp2epiu; flipud(prof_a_mp2epiu - prof_s_mp2epiu)];
  66. y_patch_mp2epic = [prof_a_mp2epic + prof_s_mp2epic; flipud(prof_a_mp2epic - prof_s_mp2epic)];
  67. fill( x_patch, y_patch_mp2rage, [0.5, 0.5, 0.5], 'EdgeColor', 'none', 'FaceAlpha', 0.4 ) ;
  68. plot( x_axis , prof_a_mp2rage, 'black', 'LineWidth', 2.5 ) ;
  69. ru = prof_a_mp2rage(idx_GM_start_mp2rage)/prof_a_mp2epiu(idx_GM_start_mp2epiu) ;
  70. fill( x_patch, y_patch_mp2epiu*ru, [0.8, 0.8, 1.0], 'EdgeColor', 'none', 'FaceAlpha', 0.4 ) ;
  71. plot( x_axis , prof_a_mp2epiu*ru, 'blue', 'LineWidth', 2.5 ) ;
  72. rc = prof_a_mp2rage(idx_GM_start_mp2rage)/prof_a_mp2epic(idx_GM_start_mp2epic) ;
  73. fill( x_patch, y_patch_mp2epic*rc, [1.0, 0.8, 0.8], 'EdgeColor', 'none', 'FaceAlpha', 0.4 ) ;
  74. plot( x_axis , prof_a_mp2epic*rc, 'red', 'LineWidth', 2.5 ) ;

cmp_subpx_prof.m at commit 3a0a37b, no license · at the source

Overview

Authors: Seong Dae Yun1, Patricia Pais-Roldán1, Jeongbeen Lee1,2, N. Jon Shah1,3,4,5
ORCID iDs: Seong Dae Yun
  1. Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich,52425 Jülich, Germany
  2. Department of Brain and Cognitive Sciences, Scranton College, Ewha Womans University,Seoul, Republic of Korea
  3. Institute of Neuroscience and Medicine 11, INM-11, JARA, Forschungszentrum Jülich,Jülich, Germany
  4. JARA - BRAIN - Translational Medicine, Aachen, Germany
  5. Department of Neurology, RWTH Aachen University,Aachen, Germany
Institutions: Forschungszentrum Jülich (Germany); Ewha Womans University (South Korea); RWTH Aachen University (Germany)
Journal: Scientific reports, volume 16, issue 1, article 19182
Dates: received 12 August 2025; accepted 12 June 2026; published online 19 June 2026
Type: Research article · Language: English
License: CC BY
Identifiers: DOI 10.1038/s41598-026-58377-2 · PMID 42321384 · PMCID PMC13282486 · OpenAlex W7165368365
Open access: gold, a free copy (OpenAlex)
Status: code verified (how the code is found and verified)
Categories: fMRI (modality), human (organism), methods / tools (subfield)
Methods: Connectivity, Machine learning, fMRI & imaging
Keywords: Geometric distortion correction, Distortion-matched Anatomy, EPI, FMRI, Functional mapping accuracy, MP2RAGE, Anatomy, Biological techniques, Medical research, Neuroscience
MeSH: Brain*, Brain Mapping*, Echo-Planar Imaging*, Image Processing, Computer-Assisted*, Magnetic Resonance Imaging*, Algorithms, Humans (* major topic)
Topic: Advanced MRI Techniques and Applications (Radiology, Nuclear Medicine and Imaging, Medicine), according to OpenAlex
Funding: Forschungszentrum Jülich GmbH (4205)
Citations: not cited yet (Europe PMC); 52 references in the paper

Abstract

Echo-planar imaging (EPI), commonly employed in functional MRI (fMRI), is highly susceptible to magnetic field inhomogeneities, leading to pronounced geometric distortions in reconstructed images. These distortions can result in substantial structural discrepancies between EPI and anatomical images acquired using the magnetization-prepared 2 rapid acquisition gradient echoes (MP2RAGE) method, thereby making it challenging to achieve accurate co-registration and subsequent localization of functional mapping. This issue can be effectively addressed by employing an anatomical imaging sequence that exhibits distortion profiles identical to those in EPI, referred to here as MP2EPI (magnetization-prepared 2 EPI). While this approach enables effortless co-registration with functional scans, it also introduces geometric distortions into the anatomical reference imaging, which limits its utility for analyses that rely on morphometric measurements or atlas-based segmentation. Distortion in MP2EPI can be corrected using additional data acquired with the reversed phase-encoding (PE) direction, which, however, significantly increases total acquisition time. To overcome this limitation, this work presents a novel MP2EPI sequence that simultaneously acquires reversed PE data within a single MP2EPI acquisition, without increasing the overall scan time. The primary focus of the current work is the technical implementation and validation of this sequence in the context of submillimeter fMRI at 7T.

Supplementary Information: The online version contains supplementary material available at 10.1038/s41598-026-58377-2.

Reproduced under the paper's license (CC BY), from the paper cited above.

Repository

Its files are read in the Code ↔ Paper reader above.

SeongDaeYun/NovelMP2EPI

License: none: the authors keep all their rights
State: the link answers, verified on 27 September 2026
Evidence: files inventoried
Commit: 3a0a37b8d98bcde2f4739cf42c5dfd06fef58f04, 15 June 2026
Languages: MATLAB (2), Shell (1)
Size: 4 files, 3 scripts
Software Heritage: not archived
Found in: “Data availability”
Holds: README
Not found: license file, CITATION.cff, environment file, tests, continuous integration, documentation
Tools: FreeSurfer (1 file), Image Processing Toolbox (1 file)
Availability: 1 check, the latest on 27 September 2026: the link answers
  • 27 September 2026: the link answers
4 files

The paper's code and data availability statement is in the Data section.

Tracing map

Proposed by the machine: these links were found in the paper and verified at the source, without human review. The map will receive a Zenodo DOI once one of the paper's authors has validated it with their ORCID.

What the map holds:

  • 1 repository of the authors' code, each at its verified commit, with its license and how the link was found in the paper;
  • 3 scripts, each with its path and the digest of its content;
  • no match between paragraphs and code yet;
  • neither the text of the paper nor the code itself.

Its JSON (tracing-map.json) is deposited on Zenodo with its DOI once the map is validated.

Data

No dataset and no data link were found in the paper.

Data availability

This study presents human in vivo brain data, the sharing of which may raise concerns regarding the protection of personal data and privacy. The Council of Europe’s policy on data protection specifically applies to health-related data (CM/Rec(2019)2), and ethical guidelines and internal administrative documents further ensure the confidentiality of in vivo data and any metadata derived from the original data. Data sharing is available upon request to Prof. N. Jon Shah under a formal data-sharing agreement. Sharing is contingent on the consent of the subjects whose data are involved, and they will be informed in advance. The custom scripts used for image processing and analysis in this study are publicly available at: https://github.com/SeongDaeYun/NovelMP2EPI.

Reproduced under the paper's license (CC BY), from the paper cited above.

Versions

The history of this record: each version stored by the harvester or made by a correction of its authors or of the maintainers of its code, and what changed in its facts. The texts of the paper (its abstract, its availability statements) are not part of it; versions that changed only those are not listed.

Version 1, 27 September 2026: the first record

Recorded: type, language, journal, volume, issue, pages, dates, 4 authors, 10 keywords, 7 MeSH terms, 1 funder, 50 references.

Cite

This paper

Yun, S. D., Pais-Roldán, P., Lee, J., & Shah, N. J. (2026). A novel distortion-matched anatomical imaging sequence for high-fidelity functional mapping in submillimeter-resolution fMRI. Scientific reports, 16(1), 19182. https://doi.org/10.1038/s41598-026-58377-2

BibTeX

@article{yun2026novel,
author = {Yun, Seong Dae and Pais-Roldán, Patricia and Lee, Jeongbeen and Shah, N. Jon},
title = {{A novel distortion-matched anatomical imaging sequence for high-fidelity functional mapping in submillimeter-resolution fMRI}},
journal = {Scientific reports},
year = {2026},
month = jun,
volume = {16},
number = {1},
pages = {19182},
publisher = {Nature Publishing Group},
issn = {2045-2322},
doi = {10.1038/s41598-026-58377-2},
url = {https://doi.org/10.1038/s41598-026-58377-2},
pmid = {42321384},
pmcid = {PMC13282486}
}

RIS

TY - JOUR
AU - Yun, Seong Dae
AU - Pais-Roldán, Patricia
AU - Lee, Jeongbeen
AU - Shah, N. Jon
TI - A novel distortion-matched anatomical imaging sequence for high-fidelity functional mapping in submillimeter-resolution fMRI
T2 - Scientific reports
J2 - Sci Rep
PY - 2026
DA - 2026/06/19
VL - 16
IS - 1
SP - 19182
SN - 2045-2322
PB - Nature Publishing Group
DO - 10.1038/s41598-026-58377-2
UR - https://doi.org/10.1038/s41598-026-58377-2
LA - en
ER -

CSL-JSON

{
"id": "10.1038/s41598-026-58377-2",
"type": "article-journal",
"title": "A novel distortion-matched anatomical imaging sequence for high-fidelity functional mapping in submillimeter-resolution fMRI",
"container-title": "Scientific reports",
"author": [
{
"family": "Yun",
"given": "Seong Dae"
},
{
"family": "Pais-Roldán",
"given": "Patricia"
},
{
"family": "Lee",
"given": "Jeongbeen"
},
{
"family": "Shah",
"given": "N. Jon"
}
],
"container-title-short": "Sci Rep",
"volume": "16",
"issue": "1",
"page": "19182",
"DOI": "10.1038/s41598-026-58377-2",
"PMID": "42321384",
"PMCID": "PMC13282486",
"ISSN": "2045-2322",
"publisher": "Nature Publishing Group",
"URL": "https://doi.org/10.1038/s41598-026-58377-2",
"language": "en",
"issued": {
"date-parts": [
[
2026,
6,
19
]
]
}
}

The tracing map gets a citation of its own once an author has validated it and it has a DOI.

Similar papers

The papers with a page that share the most with this one: the tools found in their code, their categories, datasets, cited references and authors, the rarest counting most.

[1] doi:10.1016/j.neuroimage.2021.118641 [code]
Simultaneous pure T<sub>2</sub> and varying T<sub>2</sub>'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses.
Journal: NeuroImage
In common: FreeSurfer, Image Processing Toolbox, fMRI, 8 references
[2] doi:10.1162/imag_a_00140 [code]
Unlocking near-whole-brain, layer-specific functional connectivity with 3D VAPER fMRI.
Journal: Imaging neuroscience (Cambridge, Mass.)
In common: FreeSurfer, fMRI, 8 references
[3] doi:10.1016/j.neuroimage.2023.120294 [code]
Mitigating susceptibility-induced distortions in high-resolution 3DEPI fMRI at 7T.
Journal: NeuroImage
In common: Image Processing Toolbox, fMRI, 7 references
[4] doi:10.3389/fnins.2023.1151544 [code]
Cortical depth-dependent human fMRI of resting-state networks using EPIK.
Journal: Frontiers in neuroscience
In common: fMRI, 4 references, author Seong Dae Yun
[5] doi:10.3389/fnins.2025.1537026 [code]
Mapping curvature domains in human V4 using CBV-sensitive layer-fMRI at 3T.
Journal: Frontiers in neuroscience
In common: FreeSurfer, Image Processing Toolbox, fMRI, 6 references
[6] doi:10.1002/hbm.26094 [code]
Modelling the depth-dependent VASO and BOLD responses in human primary visual cortex.
Journal: Human brain mapping
In common: Image Processing Toolbox, fMRI, 7 references
[7] doi:10.1098/rstb.2023.0085
Closed-loop fMRI at the mesoscopic scale of columns and layers: Can we do it and why would we want to?
Journal: Philosophical transactions of the Royal Society of London. Series B, Biological sciences
In common: fMRI, 7 references
[8] doi:10.1016/j.isci.2025.112967 [code]
Contextual responses drive a unique laminar signature in human V1.
Journal: iScience
In common: FreeSurfer, Image Processing Toolbox, 5 references
[9] doi:10.1038/s41598-026-37599-4 [code]
Impact of thermal and physiological denoising on laminar functional connectivity.
Journal: Scientific reports
In common: Image Processing Toolbox, fMRI, 6 references
[10] doi:10.1162/imag_a_00532 [code]
Characterizing BOLD activation patterns in the human hippocampus with laminar fMRI.
Journal: Imaging neuroscience (Cambridge, Mass.)
In common: Image Processing Toolbox, fMRI, 6 references

Contribute

The authors of this paper can claim it, correct its record and validate its tracing map, and the maintainers of its code (its owner, or a public member of its organization) correct what it says of their repository; anyone signed in can ask for its removal. Every request goes to OSCR's own machine, which answers it; your account page follows them.

Sign in with ORCID to claim this paper as one of its authors, correct its record or validate its tracing map: when the paper's metadata lists your ORCID iD, you are recognized at once. Maintainers of its code: sign in with GitHub, then claim the repository on your account page.

Add the badge to the code's README

OSCR: the badge of this paper

If you are an author or a maintainer of this paper's code, you can add this badge. It says what OSCR knows of the paper (its code, its validated tracing map) and links the code to this page. Paste one of these snippets under the README's title. Keep the two marks around it, so that the badge can be replaced in place and is never added twice. OSCR changes nothing in your repository.

Markdown
<!-- oscr-badge:start -->
[![OSCR](https://openscicode.org/badge/doi/10.1038/s41598-026-58377-2.svg)](https://openscicode.org/badge/doi/10.1038/s41598-026-58377-2)
<!-- oscr-badge:end -->
reStructuredText
.. oscr-badge:start

.. image:: https://openscicode.org/badge/doi/10.1038/s41598-026-58377-2.svg
   :target: https://openscicode.org/badge/doi/10.1038/s41598-026-58377-2
   :alt: OSCR

.. oscr-badge:end
HTML
<!-- oscr-badge:start -->
<a href="https://openscicode.org/badge/doi/10.1038/s41598-026-58377-2"><img src="https://openscicode.org/badge/doi/10.1038/s41598-026-58377-2.svg" alt="OSCR"></a>
<!-- oscr-badge:end -->

On GitHub, open the README, choose Edit (the pencil), paste the snippet under the title, then "Commit changes".

If you choose to, you can have the badge kept up to date for you, with oscr badge --write from the command line or with the GitHub Action in your repository's workflows. Every other form and option (a card, AsciiDoc, LaTeX, shields.io) is on the badge page.

Request its removal

To ask OSCR to remove this record, the copies of its authors' scripts or its tracing map, use the removal request page: signed in, you say who you are, what to remove and why, then review and confirm the request. Published rules decide every request (how).

Discussion, reproductions, activity

Discussion: code errors and mismatches between the code and the paper about this paper and its code, from readers and its authors, beside the paper and its tracing map.

Report a mismatch between the code and the paper · Report a code error (signed in)

Reproductions: reports from readers who ran the authors' code and did not get the paper's result, what they ran, with which environment, commit and data.

Report a reproduction failure (signed in)

Versions of its code: the releases of its code tied to a version of this paper (the preprint, the accepted manuscript, the version of record…), each with the tracing map versioned with it.

Activity: what happens around this paper: new versions of its record, its map's validation, discussions and reproductions. It opens with sign-in.