Significance: Cerebral water fraction is physiologically relevant to brain fluid dynamics, glymphatic function, cerebral edema, and dehydration, yet it is not routinely measured in wearable neuroimaging.
Aim: We aimed to develop and validate a low-cost, wearable, light-emitting diode (LED)-based continuous-wave near-infrared spectroscopy system capable of concurrently monitoring changes in cerebral hemoglobin concentration and water fraction from the forehead.
Approach: Our device, called the GS-FlexNIRS, contains nine LEDs spanning 740 to 1050 nm mounted on a flexible printed circuit board. Three of these wavelengths (i.e., 910, 940, and 1050 nm) fall within the water absorption window. A wavelength-weighted fitting algorithm incorporates measured LED emission spectra and photodiode responsivity to enable accurate chromophore recovery despite spectrally broad LED illumination. Performance was characterized in liquid phantoms and in five healthy participants during respiratory maneuvers.
Results: The system achieved a dynamic range of ∼100 dB, gain linearity (R2>0.99997), and signal-to-noise ratio of 67 to 90 dB. Phantom experiments confirmed independent tracking of hemoglobin deoxygenation and water fraction changes. Hemoglobin responses in human measurements were consistent with prior work.
Conclusions: The GS-FlexNIRS (∼$350/
Reproduced under the paper's license (CC BY), from the paper cited above.
Code
The paper says that its authors' code is available on request: it was not published with the paper, so there is nothing to verify.
The paper's code and data availability statement is in the Data section.
Tracing map
A tracing map links a paper to the code its authors published: this paper has none (its code is available on request), so it has no map.
Data
No dataset and no data link were found in the paper.
Code and Data Availability
The data that support the findings of this study are available from the corresponding author upon reasonable request. The analysis code used in this study is available from the corresponding author upon reasonable request.
Reproduced under the paper's license (CC BY), from the paper cited above.
Versions
The history of this record: each version stored by the harvester or made by a correction of its authors or of the maintainers of its code, and what changed in its facts. The texts of the paper (its abstract, its availability statements) are not part of it; versions that changed only those are not listed.
Version 1, 30 October 2026: the first record
Recorded: type, language, journal, volume, issue, pages, dates, 8 authors, 6 keywords, 14 MeSH terms, 1 funder, 70 references.
Cite
This paper
Wu, K. C., Renna, M., Otic, N., Starkweather, Z., Kierul, O. S., Smith, C., Franceschini, M. A., & Robinson, M. B. (2026). Development and validation of a low-cost, wearable near-infrared spectroscopy system for quantifying tissue water fraction in the human brain. Journal of biomedical optics, 31(10), 106006. https://
BibTeX
@article{wu2026developme
author = {Wu, Kuan Cheng and Renna, Marco and Otic, Nikola and Starkweather, Zachary and Kierul, Olivia S and Smith, Christopher and Franceschini, Maria Angela and Robinson, Mitchell B},
title = {{Development and validation of a low-cost, wearable near-infrared spectroscopy system for quantifying tissue water fraction in the human brain}},
journal = {Journal of biomedical optics},
year = {2026},
month = oct,
volume = {31},
number = {10},
pages = {106006},
publisher = {Society of Photo-Optical Instrumentation Engineers},
issn = {1083-3668},
doi = {10.1117/
url = {https://
pmid = {42953459},
pmcid = {PMC13715939}
}
RIS
TY - JOUR
AU - Wu, Kuan Cheng
AU - Renna, Marco
AU - Otic, Nikola
AU - Starkweather, Zachary
AU - Kierul, Olivia S
AU - Smith, Christopher
AU - Franceschini, Maria Angela
AU - Robinson, Mitchell B
TI - Development and validation of a low-cost, wearable near-infrared spectroscopy system for quantifying tissue water fraction in the human brain
T2 - Journal of biomedical optics
J2 - J Biomed Opt
PY - 2026
DA - 2026/
VL - 31
IS - 10
SP - 106006
SN - 1083-3668
PB - Society of Photo-Optical Instrumentation Engineers
DO - 10.1117/
UR - https://
LA - en
ER -
CSL-JSON
{
"id": "10.1117/
"type": "article-journal",
"title": "Development and validation of a low-cost, wearable near-infrared spectroscopy system for quantifying tissue water fraction in the human brain",
"container-title": "Journal of biomedical optics",
"author": [
{
"family": "Wu",
"given": "Kuan Cheng"
},
{
"family": "Renna",
"given": "Marco"
},
{
"family": "Otic",
"given": "Nikola"
},
{
"family": "Starkweather",
"given": "Zachary"
},
{
"family": "Kierul",
"given": "Olivia S"
},
{
"family": "Smith",
"given": "Christopher"
},
{
"family": "Franceschini",
"given": "Maria Angela"
},
{
"family": "Robinson",
"given": "Mitchell B"
}
],
"container-title-short":
"volume": "31",
"issue": "10",
"page": "106006",
"DOI": "10.1117/
"PMID": "42953459",
"PMCID": "PMC13715939",
"ISSN": "1083-3668",
"publisher": "Society of Photo-Optical Instrumentation Engineers",
"URL": "https://
"language": "en",
"issued": {
"date-parts": [
[
2026,
10,
28
]
]
}
}
Similar papers
The papers with a page that share the most with this one: the tools found in their code, their categories, datasets, cited references and authors, the rarest counting most.
- [1] doi:10.1117/1.nph.13.2.025008
- Comparative validation of speckle contrast optical spectroscopy against diffuse correlation spectroscopy for monitoring human cerebral blood flow.Journal: NeurophotonicsIn common: 7 references, 3 authors
- [2] doi:10.1117/1.nph.9.s2.s24001 [code]
- Optical imaging and spectroscopy for the study of the human brain: status report.Journal: NeurophotonicsIn common: fNIRS, methods / tools, 8 references, author Maria Angela Franceschini
- [3] doi:10.1038/s42003-025-08915-x [code]
- Mapping human cerebral blood flow with high-density, multi-channel speckle contrast optical spectroscopy.Journal: Communications biologyIn common: 1 reference, 2 authors
- [4] doi:10.1038/s41598-024-62106-y
- Choosing a camera and optimizing system parameters for speckle contrast optical spectroscopy.Journal: Scientific reportsIn common: 1 reference, 2 authors
- [5] doi:10.1117/1.nph.11.3.035002 [code]
- Flexible circuit-based spatially aware modular optical brain imaging system for high-density measurements in natural settings.Journal: NeurophotonicsIn common: fNIRS, 6 references
- [6] doi:10.1117/1.nph.13.2.025001 [code]
- Surface-based image reconstruction optimization for high-density functional near-infrared spectroscopy.Journal: NeurophotonicsIn common: fNIRS, 5 references
- [7] doi:10.1038/s41551-025-01394-9 [code]
- A wireless device for continuous measurement of brain parenchymal resistance tracks glymphatic function in humans.Journal: Nature biomedical engineeringIn common: methods / tools, 6 references
- [8] doi:10.1117/1.nph.13.2.025003 [code]
- Monte Carlo simulations of time-resolved blood flow index: times-of-flight beyond ∼1 ns are necessary for brain-dominated measurements.Journal: NeurophotonicsIn common: 5 references
- [9] doi:10.1162/imag_a_00331 [code]
- Assessing the consistency and sensitivity of the neural correlates of narrative stimuli using functional near-infrared spectroscopy.Journal: Imaging neuroscience (Cambridge, Mass.)In common: fNIRS, 5 references
- [10] doi:10.1073/pnas.2528913123 [code]
- Sleep deprivation exhibits an age-dependent effect on infraslow global brain activity.Journal: Proceedings of the National Academy of Sciences of the United States of AmericaIn common: 6 references
Contribute
The authors of this paper can claim it, correct its record and validate its tracing map, and the maintainers of its code (its owner, or a public member of its organization) correct what it says of their repository; anyone signed in can ask for its removal. Every request goes to OSCR's own machine, which answers it; your account page follows them.
Sign in with ORCID to claim this paper as one of its authors, correct its record or validate its tracing map: when the paper's metadata lists your ORCID iD, you are recognized at once. Maintainers of its code: sign in with GitHub, then claim the repository on your account page.
Claim this paper
Correct its record
Say what each link of this record is, remove the ones that are not the paper's, add the ones that are missing. The correction becomes a new version of the record, in its Versions section.
Request its removal
To ask OSCR to remove this record, the copies of its authors' scripts or its tracing map, use the removal request page: signed in, you say who you are, what to remove and why, then review and confirm the request. Published rules decide every request (how).
Discussion, reproductions, activity
Discussion: code errors and mismatches between the code and the paper about this paper and its code, from readers and its authors, beside the paper and its tracing map.
Reproductions: reports from readers who ran the authors' code and did not get the paper's result, what they ran, with which environment, commit and data.
Activity: what happens around this paper: new versions of its record, its map's validation, discussions and reproductions. It opens with sign-in.